| 回路阻抗 | |||||
|---|---|---|---|---|---|
| 功能 | LOOP ATT | LOOP HIGH | |||
| L-PE/L-N (3線) | L-PE(2線) | L-PE (0.01ΩRes) | L-PE (0.001ΩRes) 高測試電流(25A) | L-N/L-L | |
| 額定電壓 | 100-260V (50/60Hz) | 48-260V (50/60Hz) | 48-260V (50/60Hz) | 100-260V (50/60Hz) | 48-500V (50/60Hz) |
| 測量范圍 | 20.00/200.0/2000? (自動量程) | 20.00/200.0/ 2000? (自動量程) | 2.000Ω | 20.00Ω | |
| 精確度 | ±3%rdg±6dgt | ±3%rdg±10dgt | ±3%rdg±4dgt | ±3%rdg±25mΩ | ±3%rdg±4dgt |
| 0Ω外部回路額定測試電流: 230V時的數(shù)量/時間 | L-N:6A/60ms N-PE:10mA | L-PE:15mA | 20Ω: 6A/20ms 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms | 25A/20ms | 6A/20ms |
| PSC/PFC | |||||
|---|---|---|---|---|---|
| 范圍 | 2000A/20kA | 2000A/20kA (PFC) | 2000A/20kA (PFC) | 2000A/50kA (PFC) | 2000A/20kA (PSC) |
| 精確度 | PSC/PFC 精度來自于測量的回路阻抗規(guī)范和測量的電壓規(guī)范 | ||||
| RCD | ||||||||
|---|---|---|---|---|---|---|---|---|
| 額定電壓 | 100-260V(50/60Hz) | |||||||
| 功能 | x1/2, x1,x5,Ramp,自動,Uc | |||||||
| 6/10/30/100/300/500/1000mA/變量 | ||||||||
| RCD型 | AC(G/S) | A(G/S) | F(G/S) | B(G/S) | EV | |||
| 跳脫電流設(shè)置 | x1/2, x1,Uc | 10/30/100/300/ 500/1000mA(G) 10/30/100/ 300/500(S) | 10/30/100/ 300/500mA | 10/30/100/ 300/500mA | 10/30/100/ 300mA | 6mA(x1僅) | ||
| x5 | 10/30/100mA | 10/30/100mA | 10/30/100mA | 10/30mA | - | |||
| Ramp | 10/30/100/ 300/500mA | 10/30/100/ 300/500mA | 10/30/100/ 300/500mA | 10/30/100/ 300mA | 6mA | |||
| 精確度 | ||||||||
| 跳脫電流 | x1/2 | -8% - -2% | -10% - 0% | -10% - 0% | -10% - 0% | - | ||
| x1 | +2% - +8% | 0% - +10% | 0% - +10% | 0% - +10% | 0% - +10% | |||
| x5 | +2% - +8% | 0% - +10% | 0% - +10% | 0% - +10% | - | |||
| Ramp | -4% - +4% | -10% - +10% | -10% - +10% | -10% - +10% | -10% - +10% | |||
| 跳脫時間 | x1/2 | 2000ms(G/S):±1%rdg±2ms | - | |||||
| x1 | 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms | 10.5s:±1%±2? | ||||||
| x5 | 410ms(G/S):±1%rdg±2ms | - | ||||||
| 導(dǎo)通測試 | ||||
|---|---|---|---|---|
| 范圍 | 20.00/200.0/2000? (自動量程) | |||
| 開路電壓(DC) | 7-14V | |||
| 測量電流 | 200mA | >200mA or more(小于2?) | ||
| 15mA | 15mA±3mA(短路) | |||
| 精確度 | ±2%rdg±8dgt | |||
| 電壓測試 | ||||
|---|---|---|---|---|
| 范圍 | 300.0/600V(自動量程) | |||
| 測量范圍 | 電壓 | 2-600V | ||
| 頻率 | 45-65Hz | |||
| 精確度 | 電壓 | ±2%rdg±4dgt | ||
| 頻率 | ±0.5%rdg±2dgt | |||
| 相位旋轉(zhuǎn) | ||||
|---|---|---|---|---|
| 額定電壓 | 48-600V(50/60Hz) | |||
| 標(biāo)志 | 正確相序: 顯示“1.2.3”和標(biāo)志 反相相序: 顯示“3.2.1” 和標(biāo)志 | |||
| 接地測試 | ||||
|---|---|---|---|---|
| 范圍 | 20.00/200.0/2000Ω(自動量程) | |||
| 精確度 | ±2%rdg±0.08Ω(20.00Ω) ±2%rdg±3dgt(200.0/2000Ω) | |||
8212-USB(USB適配器"KEW Report(軟件)'')
LR6(AA) × 8, 使用說明書, 檢驗證書
可選件8259(適配器)
7272(測試線)
8017A(延長探棒)
有任何疑問,請及時與我們溝通!期待您的電鈴!
電話:0755-89686581
13265803631/鴻澤


















第5年
通過認(rèn)證 





克列茨MODEL 8082延長探針|MODEL808
克列茨MODEL 3124S兆歐表|3124絕緣
克列茨KEW 2056R電流鉗形表|KEW2056
克列茨MODEL 4118A回路電阻測試儀|4
克列茨MODEL 7100測試線|MODEL7100
克列茨MODEL 7129A測試線|MODEL7129
克列茨MODEL KAMP10 IEC標(biāo)準(zhǔn)插頭測
克列茨MODEL 7127A測試線|MODEL7127
克列茨MODEL 7158B安全鱷魚夾|MODEL
克列茨MODEL 8216溫度探棒|MODEL821
微信客服